Back to Products
E Motor Protection And Control  
Universal contactor  
060  
CJX2S ----------------------------------------------------------------------------------- 060-061  
CJX2SF --------------------------------------------------------------------------------------- 062  
CDC8 ------------------------------------------------------------------------------------------ 064  
Thermal relay  
063  
JRS1DSP------------------------------------------------------------------------------------- 063  
CDR8 ------------------------------------------------------------------------------------------ 065  
Contactor relay  
JZC4s------------------------------------------------------------------------------------------ 065  
Motor circuit breaker 066  
065  
CDP6-32-------------------------------------------------------------------------------------- 066  
CDPV2s--------------------------------------------------------------------------------------- 066  
Electromagnetic starter  
067  
CDS2S ---------------------------------------------------------------------------------------- 067  
Electric control and protection switch  
068  
CDK1 ------------------------------------------------------------------------------------------ 068  
Motor protector  
069  
JD-5 -------------------------------------------------------------------------------------------- 069  
JD-6 -------------------------------------------------------------------------------------------- 069  
CDS16----------------------------------------------------------------------------------------- 069  
Miniature electromagnetic relay  
070-074  
CDZ9------------------------------------------------------------------------------------------- 070  
CDZ9-62P ------------------------------------------------------------------------------------ 070  
JQX-10F -------------------------------------------------------------------------------------- 071  
JQX-15F -------------------------------------------------------------------------------------- 072  
JQX-3FF -------------------------------------------------------------------------------------- 072  
JQX-62F -------------------------------------------------------------------------------------- 073  
Selection Guide  
CJX2s AC Contactor  
Product model  
CJX2s  
Current spec.  
06  
Aux. contact  
10  
Coil voltage  
M
Coil freq.  
06: 6A  
...  
10: 1NO+0NC  
01: 0NO+1NC  
11: 1NO+1NC  
B: 24V  
No: 50Hz  
...  
7: 50/60Hz  
95: 95A  
M: 220V/230V  
...  
Q: 380V/400V  
...  
Rated  
current Ie  
Rated  
current Ie  
(A)  
Aux. contact  
Normally open NO Normally closed NC  
Aux. contact  
Normally open NO Normally closed NC  
Motor power Pe  
(KW AC-3,380V)  
Motor power Pe  
(KW AC-3,380V)  
Order code  
Order code  
(A)  
2.2  
6
1
-
-
1
-
CJX2s 06 10 *  
CJX2s 06 01 *  
CJX2s 09 10 *  
CJX2s 09 01 *  
CJX2s 09 11 *  
CJX2s 12 10 *  
CJX2s 12 01 *  
CJX2s 12 11 *  
CJX2s 16 10 *  
CJX2s 16 01 *  
CJX2s 16 11 *  
CJX2s 18 10 *  
CJX2s 18 01 *  
CJX2s 18 11 *  
CJX2s 22 10 *  
CJX2s 22 01 *  
CJX2s 22 11 *  
11  
25  
32  
38  
1
-
-
CJX2s 25 10 *  
CJX2s 25 01 *  
CJX2s 25 11 *  
CJX2s 32 10 *  
CJX2s 32 01 *  
CJX2s 32 11 *  
CJX2s 38 10 *  
CJX2s 38 01 *  
CJX2s 38 11 *  
CJX2s 40 11 *  
CJX2s 50 11 *  
CJX2s 65 11 *  
CJX2s 80 11 *  
CJX2s 95 11 *  
1
1
-
4
9
1
-
1
1
-
1
1
-
15  
1
1
-
1
1
-
5.5  
5.5  
7.5  
11  
12  
16  
18  
22  
1
1
-
1
1
-
18.5  
1
1
-
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
-
18.5  
22  
40  
50  
65  
80  
95  
1
1
-
30  
1
1
-
37  
1
1
-
45  
Notes: 3-pole is the conventional pole, and is not indicated in the model  
The * in the CJX2s order code can be indicated by the coil voltage code  
Coil frequency 50Hz is a conventional frequency, and is not indicated in the model.  
50Hz is available for all coil voltages, and 50/60Hz are also available  
1
1
1
Coil voltage code  
Coil voltage (V)  
*
24  
36  
C
48  
E
110  
F
127  
S
220/230  
M
240  
U
380/400  
Q
415  
L
440  
X
B
060  
Selection Guide  
Product model  
CJX2s  
Current spec.  
120  
Aux. Contact  
Coil voltage  
M
Coil frequency  
7
120: 120A  
160: 160A  
185: 185A  
225: 225A  
265: 265A  
330: 330A  
400: 400A  
Default: 2NO+2NC  
F: AC/DC 110V  
S: AC/DC 127V  
M: AC/DC 220V  
Q: AC/DC 380V  
Default: 50Hz  
7: 50/60Hz  
Instantaneous aux.  
contact  
Instantaneous aux.  
contact  
AC-3,380/400V  
AC-3,380/400V  
Rated current (A) Rated power (kW)  
Order code  
Order code  
Rated current (A) Rated power (kW)  
120  
160  
185  
225  
55  
2
2
2
2
2
2
2
2
CJX2H-120 □□  
CJX2H-160 □□  
CJX2H-185 □□  
CJX2H-225 □□  
265  
330  
400  
132  
160  
220  
2
2
2
2
2
2
CJX2H-265 □□  
CJX2H-330 □□  
CJX2H-400 □□  
75  
90  
110  
Note: “□□” indicates the coil voltage code  
Coil voltage codes table  
Coil voltage (V)  
50Hz  
110  
F
127  
S
220  
M
380  
Q
50/60Hz  
-
-
-
-
061  
Selection Guide  
CJX2sF High-Current AC Contactor  
Product model  
Current spec.  
115  
Aux. contact  
00  
Coil voltage  
M
Coil freq.  
CJX2sF  
115: 115A  
...  
00: 0NO+0NC  
B: 24V  
...  
Default: 50Hz  
7: 50/60Hz  
2100: 2100A  
X: 440V  
Instantaneouly  
aux. contact  
Instantaneous aux.  
contact  
AC-3,380/400V  
AC-3,380/400V  
Rated current (A) Rated power (kW)  
Order code  
Order code  
Rated current (A) Rated power (kW)  
115  
150  
185  
225  
265  
330  
400  
500  
55  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
CJX2sF 115 00 □□  
CJX2sF 150 00 □□  
CJX2sF 185 00 □□  
CJX2sF 225 00 □□  
CJX2sF 265 00 □□  
CJX2sF 330 00 □□  
CJX2sF 400 00 □□  
CJX2sF 500 00 □□  
630  
335  
450  
630  
780  
870  
1000  
1250  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
CJX2sF 630 00 □□  
CJX2sF 800 00 □□  
CJX2sF 1000 00 □□  
CJX2sF 1250 00 □□  
CJX2sF 1450 00 □□  
CJX2sF 1700 00 □□  
CJX2sF 2100 00 □□  
75  
800  
90  
1000  
1250  
1450  
1700  
2100  
110  
132  
160  
200  
Note: “□□” indicates the coil voltage code  
Product model  
CJX2sF  
Current spec.  
115  
Main contact  
4
Coil voltage  
M
Coil freq.  
115: 115A  
...  
4: Normally open  
F: 110 V  
...  
7: 50/60Hz  
800: 800A  
M: 220-230V  
Q: 380-400V  
Coil voltage codes table  
Coil voltage (V)  
50Hz  
36  
C
-
110  
F
127  
S
220  
M
380  
Q
400  
V
440  
X
50/60Hz  
F7  
-
M7  
Q7  
-
-
062  
Selection Guide  
JRS1Dsp Thermal Overload Relay  
Product model  
JRS1Dsp  
Frame current  
25  
Setting current  
P16  
Installation method  
25: 25A  
P16: 0.1~0.16A  
...  
Default: Combination installation  
38: 38A  
93: 93A  
93: 80~93A  
630: 265~630A  
185: 185A  
630: 630A  
Note: P means decimal point  
Spec. of matched fuse Spec. of matched contactor  
Rated Spec. of matched fuse Spec. of matched contactor  
current Ie  
(A)  
Frame Rated current  
current  
Frame  
current  
Order code  
Order code  
Ie (A)  
Normally open NO Normally closed NC  
Normally open NO Normally closed NC  
120~225  
0.1~0.16  
0.16~0.25  
0.25~0.4  
0.4~0.63  
0.63~1  
1~1.6  
4
4
-09~38  
-09~38  
-09~38  
-09~38  
-09~38  
-09~38  
-09~38  
-09~38  
-09~38  
-09~38  
-09~38  
-12~38  
-18~38  
-25~38  
-25~38  
-32~38  
-40~95  
-40~95  
-40~95  
-40~95  
-40~95  
-40~95  
-50~95  
-50~95  
-65~95  
-80~95  
-95  
JRS1Dsp 25 P16  
JRS1Dsp 25 P25  
JRS1Dsp 25 P4  
JRS1Dsp 25 P63  
48-65  
55-70  
100  
100  
100  
125  
200  
200  
200  
250  
250  
400  
400  
500  
630  
800  
800  
JRS1Dsp 185 65  
JRS1Dsp 185 70  
JRS1Dsp 185 80  
JRS1Dsp 185 95  
JRS1Dsp 185 115  
JRS1Dsp 185 135  
JRS1Dsp 185 150  
JRS1Dsp 185 160  
JRS1Dsp 185 185  
JRS1Dsp 630 200F  
JRS1Dsp 630 250F  
JRS1Dsp 630 320F  
JRS1Dsp 630 400F  
JRS1Dsp 630 480F  
JRS1Dsp 630 630F  
4
63-80  
4
75-95  
4
JRS1Dsp 25 1 185  
JRS1Dsp 25 1P6  
JRS1Dsp 25 2P5  
JRS1Dsp 25 4  
90-115  
4
105-135  
120-150  
130-160  
150-185  
145-200  
180-250  
230-320  
290-400  
350-480  
460-630  
1.6~2.5  
2.5~4  
6
25  
10  
16  
20  
20  
25  
35  
50  
63  
80  
20  
25  
35  
50  
63  
80  
100  
100  
125  
125  
160  
4~6  
JRS1Dsp 25 6  
5.5~8  
JRS1Dsp 25 8  
265~630  
7~10  
JRS1Dsp 25 10  
9~13  
JRS1Dsp 25 13  
630  
12~18  
17~25  
23~32  
30~40  
7~10  
JRS1Dsp 25 18  
JRS1Dsp 25 25  
JRS1Dsp 38 32  
JRS1Dsp 38 40  
JRS1Dsp 93 10  
JRS1Dsp 93 13  
JRS1Dsp 93 18  
JRS1Dsp 93 25  
JRS1Dsp 93 32  
JRS1Dsp 93 40  
JRS1Dsp 93 50  
JRS1Dsp 93 65  
JRS1Dsp 93 70  
JRS1Dsp 93 80  
JRS1Dsp 93 93  
38  
9~13  
12~18  
17~25  
23~32  
30~40  
37~50  
48~65  
55~70  
63~80  
80~93  
93  
063  
Selection Guide  
CDC8 AC Contactor  
Product Name  
CDC8  
Current specification  
Auxiliary Contact  
11  
Coil Voltage  
B
Operating Mode  
Operating frequency  
9
Z
09  
12  
18  
25  
32  
40  
50  
65  
11:1NO+1NC  
B: 24V  
C: 36V  
E: 48V  
F: 110V  
Default: AC coil  
Z: DC coil operation  
N: Mechanical interlock  
7:  
50/60Hz  
S: 127V  
M: 220V/230V  
U: 240V  
Q: 380V/400V  
L: 415V  
X: 440V  
Remark:  
At present, the current specification of DC operating products is only 32 A, and the operating coils are B, E, F and M specifications.  
Pole 3 is the conventional pole number and is not indicated in the model  
AC operating coils are all 50/60Hz  
064  
Selection Guide  
CDR8 Thermal Overload Relay  
Product model  
Shell frame current  
38  
Setting current  
P16  
Installation method  
Default  
CDR8  
38: 38A  
65: 65A  
P16: 0.1-0.16A  
...  
Default: Combined installation  
65: 48-65A  
Matched fuse spec.  
Matched contactor spec.  
Shell frame current  
Setting current  
Order code  
Recommended RT16  
Recommended CDC8  
-09~38  
-09~38  
-09~38  
-09~38  
-09~38  
-09~38  
-09~38  
-09~38  
-09~38  
-09~38  
-09~38  
-09~38  
-09~38  
-09~38  
-09~38  
-09~38  
-40~65  
-40~65  
-40~65  
-40~65  
-40~65  
0.1~0.16  
0,16~0,25  
0,25~0,4  
0,4~0,63  
0.63~1  
1~1.6  
2
CDR8 38 P16  
CDR8 38 P25  
CDR8 38 P4  
CDR8 38 P63  
CDR8 38 1  
2
2
2
4
4
CDR8 38 1P6  
CDR8 38 2P5  
CDR8 38 4  
1,6~2,5  
2.5~4  
6
10  
16  
20  
20  
25  
35  
50  
63  
80  
50  
63  
100  
100  
100  
38  
4~6  
CDR8 38 6  
5.5~8  
CDR8 38 8  
7~10  
CDR8 38 10  
CDR8 38 13  
CDR8 38 18  
CDR8 38 25  
CDR8 38 32  
CDR8 38 38  
CDR8 65 25  
CDR8 65 32  
CDR8 65 40  
CDR8 65 50  
CDR8 65 65  
9~13  
12~18  
17~25  
23~32  
30~38  
17~25  
23~32  
30~40  
37~50  
48~65  
65  
JZC4s Contactor Relay  
Product model  
JZC4s  
22  
M
1
Coil frequency  
MQ  
22:2NO+2NC  
31:3NO+1NC  
40:4NO+0NC  
13:1NO+3NC  
04:0NO+4NC  
B:24V  
No: 50Hz  
...  
7: 50/60Hz  
M:220V/230V  
...  
Q:380V/400V  
...  
065  
Selection Guide  
CDP6 Motor Circuit Breaker  
Product model  
CDP6  
Frame current  
32  
Set current  
P16  
Special detection  
32: 32A  
80: 80A  
P16: 0.1-0.16A  
...  
32: 24-32A  
Default: Comply with RoHS detection standard  
P means decimal point  
Thermal trip  
Magnetic trip 400/415V, 50/60Hz, AC-3 class  
Recommended for match use  
Order code  
Standard rated power of three-  
phase motor  
Set current range  
Current Id  
Contactor model  
0.1-0.16A  
1.5A  
2.4A  
-
CDC6i-09  
CDC6i-09  
CDP6 32 P16  
CDP6 32 P25  
1.06-0.25A  
0.06KW  
0.25-0.4A  
0.4-0.63A  
0.63-1A  
1-1.6A  
5A  
0.09KW  
0.12KW  
0.25KW  
0.37KW  
0.75KW  
1.5KW  
2.2KW  
4KW  
CDC6i-09  
CDC6i-09  
CDC6i-09  
CDC6i-09  
CDC6i-09  
CDC6i-09  
CDC6i-09  
CDC6i-09  
CDC6i-12  
CDC6i-18  
CDC6i-25  
CDC6i-25  
CDC6i-32  
CDC6i-40  
CDC6i-65  
CDC6i-80  
CDP6 32 P4  
CDP6 32 P63  
CDP6 32 1  
8A  
13A  
22.5A  
33.5A  
51A  
CDP6 32 1P6  
CDP6 32 2P5  
CDP6 32 4  
1.6-2.5A  
2.5-4A  
4-6.3A  
78A  
CDP6 32 6P3  
CDP6 32 10  
CDP6 32 14  
CDP6 32 18  
CDP6 32 23  
CDP6 32 25  
CDP6 32 32  
CDP6 80 40  
CDP6 80 63  
CDP6 80 80  
6-10A  
138A  
170A  
223A  
327A  
327A  
416A  
480A  
756A  
960A  
9-14A  
5.5KW  
7.5KW  
9KW  
13-18A  
17-23A  
20-25A  
24-32A  
24-40A  
24-63A  
24-80A  
11KW  
15KW  
18.5KW  
30KW  
40KW  
CDV2s Motor Circuit Breaker  
066  
Selection Guide  
Thermal trip  
Magnetic trip 400/415V, 50/60Hz, AC-3 class  
Recommended for match use  
Order code  
Set current range  
Current Id  
Standard rated power of three-phase motor Contactor model  
0.1-0.16A  
1.06-0.25A  
0.25-0.4A  
0.4-0.63A  
0.63-1A  
1-1.6A  
1.5A  
2.4A  
5A  
-
CJX2s-0911  
CJX2s-0911  
CJX2s-0911  
CJX2s-0911  
CJX2s-0911  
CJX2s-0911  
CJX2s-0911  
CJX2s-0911  
CJX2s-0911  
CJX2s-0911  
CJX2s-1211  
CJX2s-1811  
CJX2s-2311  
CJX2s-2511  
CJX2s-3211  
CDV2s(X) 32 P16  
CDV2s(X) 32 P25  
CDV2s(X) 32 P4  
CDV2s(X) 32 P63  
CDV2s(X) 32 1  
0.06KW  
0.09KW  
0.12KW  
0.25KW  
0.37KW  
0.75KW  
1.5KW  
2.2KW  
4KW  
8A  
13A  
22.5A  
33.5A  
51A  
CDV2s(X) 32 1P6  
CDV2s(X) 32 2P5  
CDV2s(X) 32 4  
1.6-2.5A  
2.5-4A  
4-6.3A  
78A  
CDV2s(X) 32 6P3  
CDV2s(X) 32 10  
CDV2s(X) 32 14  
CDV2s(X) 32 18  
CDV2s(X) 32 23  
CDV2s(X) 32 25  
CDV2s(X) 32 32  
6-10A  
138A  
170A  
223A  
327A  
327A  
416A  
9-14A  
5.5KW  
7.5KW  
9KW  
13-18A  
17-23A  
20-25A  
24-32A  
11KW  
15KW  
CDS2s  
Product model  
CDS2s  
Frame current  
13  
Control mode  
b
Set current  
p16  
13: 13A  
32: 32A  
65: 65A  
95: 95A  
B: With button  
P16: 0.16A  
No: Without button  
95: 80-93A  
Note: P means decimal point  
Order code  
With button  
Order code  
With button  
Frame  
current (A) (A)  
Set current  
Frame  
current (A) (A)  
Set current  
Without button  
Without button  
13  
0.1~0.16  
CDS2s 13B P16 * CDS2s 13 P16 *  
32  
65  
95  
12~18  
CDS2s 32B 18 *  
CDS2s 32B 25 *  
CDS2s 32B 32 *  
CDS2s 65B 40 *  
CDS2s 65B 50 *  
CDS2s 65B 65 *  
CDS2s 95B 14 *  
CDS2s 95B 14 *  
CDS2s 32 18 *  
CDS2s 32 25 *  
CDS2s 32 32 *  
CDS2s 65 40 *  
CDS2s 65 50 *  
CDS2s 65 65 *  
CDS2s 95 14 *  
CDS2s 95 14 *  
0.16~0.25 CDS2s 13B P25 * CDS2s 13 P25 *  
17~25  
23~32  
30~40  
37~50  
48~65  
63~80  
80~93  
0.25~0.4  
0.4~0.63  
0.63~1  
1~1.6  
CDS2s 13B P4 *  
CDS2s 13B P63 * CDS2s 13 P63 *  
CDS2s 13B 01 * CDS2s 13 01 *  
CDS2s 13 P4 *  
CDS2s 13B 1P6 * CDS2s 13 1P6 *  
CDS2s 13B 2P5 * CDS2s 13 2P5 *  
1.6~2.5  
2.5~4  
CDS2s 13B 04 *  
CDS2s 13B 06 *  
CDS2s 13B 08 *  
CDS2s 13B 10 *  
CDS2s 13B 13 *  
CDS2s 13 04 *  
CDS2s 13 06 *  
CDS2s 13 08 *  
CDS2s 13 10 *  
CDS2s 13 13 *  
4~6  
Coil voltage code  
5.5~8  
Coil voltage (V) 110  
220/230  
M
380/400  
Q
7~10  
*
F
9~13  
067  
Selection Guide  
CDK1  
Frame  
current  
Controller  
type  
Rated current Aux. contact Control  
Leakage  
current  
Product name  
CDK1  
Derived code  
No  
Additional function  
of controller  
type  
voltage  
63  
M
1
02  
M
No  
1
63:63A  
1:1A  
3:3A  
6:6A  
M:220V  
Q:380V  
No: Basic type  
F: Fire control  
G: Isolation  
1: 30mA  
2: 50mA  
3: 75mA  
No  
D
M: Digital  
tube type  
02  
125:125A  
06  
D1  
D2  
J
0209  
0609  
L: Electric leakage 4: 100mA  
5: 150mA  
125:  
125A  
6: 200mA  
J2  
Z
7: 300mA  
8: 500mA  
No: Basic type  
02: 2 open + 1 closed + 1 short circuit + 1 overload  
06: 3 open + 3 closed + 1 short circuit + 1 overload  
0209: 4 open + 2 closed + 1 short circuit + 1 overload  
0609: 5 open + 4 closed + 1 short circuit + 1 overload  
D: Low-speed basic type + High speed fire control type  
D1: All are of the basic type  
D2: All are of the fire control type  
J: Star-delta voltage reducting starter  
J2: High power star-delta voltage reducting starter  
Z: Self-coupling voltage reducting starter  
Notes:  
1. The conventional default contact is 06;  
2. Fire control type: with overload alarm non-trip function.  
068  
Selection Guide  
JD-5 Motor Integrated Protector  
Rated control  
power voltage  
Product name  
JD  
Function code  
Set current  
0P5A5A:0.5A 5A  
5: Trimming potentiometer setting indicator  
220:AC220V  
380:AC380V  
5B: Trimming potentiometer setting indicator with alarm 2A20A:2A 20A  
1A80A:1A 80A  
function  
20A80A:20A 80A  
5A: Improved trimming potentiometer setting indicator  
The working power supply and the three-phase current can 1A100A:1A 100A  
be supplied asynchronously, and the current can be statically 10A100A:10A~100A  
set.  
Note: P means decimal point  
JD-6 Motor Integrated Protector  
Product name  
JD-6  
Function code  
Set current  
Rated control power voltage  
6: Normal type  
30A150A:30A-150A  
220:AC220V  
380:AC380V  
63A150A:63A 150A  
6A: Improved type  
63A400A:63A 400A  
100A250A:100A 250A  
200A500A:200A 500A  
20A400A:20A 400A  
30A150A:30A 150A  
80A400A:80A 400A  
CDS16 Intelligent Motor Protector  
Product name  
CDS16  
Current spec.  
Control power voltage Us  
100A:1A 100A  
220:AC220V  
380:AC380V  
400A:100A 400A  
800A:400A 800A  
069  
Selection Guide  
CDZ9 Series Miniature Electromagnetic Relay  
Number of contacts Lead-out terminal type  
Product name  
CDZ9  
Contact load  
5
Indicator mark Contact type  
Input voltage  
Coil voltage  
B
2
P
L
Z
D
5: 3~5A  
2: 2 sets  
3: 3 sets  
4: 4 sets  
P: Plug-in type L: LED light  
W: Welded type LS: LED light  
Test button and  
Z: Transfer  
D: DC  
T: 6V  
Default: AC  
J: 12V  
B: 24V  
C: 36V  
E: 48V  
F: 110V  
S: 127V  
M: 220V  
Q: 380V  
mechanical  
indicator window  
CDZ9-62P Series Miniature Electromagnetic Relay  
Number of contacts Lead-out terminal type  
Product name  
CDZ9  
Contact load  
6
Indicator mark Contact type  
Input voltage  
D
Coil voltage  
B
2
P
L
Z
6: 7~10A  
2: 2 sets  
P: Plug-in type L: LED light  
W: Welded type  
Z: Transfer  
D: DC  
T: 6V  
Default: AC  
J: 12V  
B: 24V  
C: 36V  
E: 48V  
F: 110V  
S: 127V  
M: 220V  
Q: 380V  
070  
Selection Guide  
JQX-10F, JTX Series Miniature Electromagnetic Relay  
Product name  
JQX  
Contact load  
10F  
Number of contacts  
2
Contact type  
Z
Input voltage  
D
Coil voltage  
B
10F: 10A  
2: 2 sets  
3: 3 sets  
4: 4 sets  
Z: Transfer  
H: Normally open  
D: Normally closed  
D: DC  
Default: AC  
T: 6V  
J: 12V  
B: 24V  
C: 36V  
E: 48V  
F: 110V  
S: 127V  
M: 220V  
Q: 380V  
Product name  
JTX  
Number of contacts  
2
Contact type  
C
Input voltage  
Coil voltage  
B
D
2: 2 sets  
3: 3 sets  
4: 4 sets  
C: Transfer  
D: DC  
Default: AC  
T: 6V  
J: 12V  
B: 24V  
C: 36V  
E: 48V  
F: 110V  
S: 127V  
M: 220V  
Q: 380V  
071  
Selection Guide  
JQX-15F Series Miniature Electromagnetic Relay  
Product name  
JQX-15F  
Coil voltage  
Contact type  
Load current  
5D:DC5V  
H: Normally open  
Z: Transfer type  
30A  
6D:DC6V  
9D:DC9V  
12D:DC12V  
15D:DC15V  
24D:DC24V  
48D:DC48V  
JQX-3FF(T73) Series Miniature Electromagnetic Relay  
Product name  
JQC-3FF  
Coil voltage  
Contact type  
Load current  
5D:DC5V  
H: Normally open  
D: Normally closed  
Z: Transfer type  
Normally open:  
Normally closed:  
6D:DC6V  
9D:DC9V  
12D:DC12V  
24D:DC24V  
48D:DC48V  
072  
Selection Guide  
JQX-62F High-Power Electro-Magnetic Relay  
Product name  
JQX-62F  
Contact form  
Load current  
Coil voltage  
1Z: One set of contacts  
2Z: One set of contacts  
100A: 1A-100A  
80A: 1A-80A  
220: AC220V  
24D: DC24V  
Product Features  
JQX-62F series electro-magnetic relay is suitable for electronic control equipment, household appliances, smart home, office automation,  
security series, commercial machinery, communication equipment, automobiles, machine tools, construction, transportation equipment, and  
instrumentation and meters for remote intermediate conversion or amplification of the element. Its leading-out terminal spacing and outline  
dimensions have been standardized, and are universal at home and abroad. It is used in rear window mist eliminator, battery circuit breaker,  
automotive air conditioner, oil pump controller, fog lamp, cooling fan control, headlight control, and start-stop control.  
Technical Parameters  
1Z: One set of conversion type  
Contact type  
2Z: Two sets of conversion type  
1Z: 100A 250VAC/30VDC  
Max. continuous current  
2Z: 80A 250VAC/30VDC  
NO end: Typical value 20mV, Max. value 250mV (measured under 10A)  
Voltage drop of contact  
NC end: Typical value 30mV, Max. value 250mV (measured under 10A)  
Max. switching current  
Max. switching voltage  
Min. load  
1Z: 100A 2Z: 80A (resistive)  
110% of rated voltage (resistive)  
1A 6VDC  
Electrical endurance  
Mechanical endurance  
Action time  
100,000 times  
1,000,000 times  
≤30ms  
Release time  
≤15ms  
Vibration  
10Hz~60Hz 035 double-amplitude 60Hz~500Hz 49m/s  
196m/s  
Impact  
Flame retardance  
Leading-out terminal type  
Package type  
Comply with UL94-HB standard requirements  
Screw-pressed connection type  
Dust-proof type  
Weight  
1Z:235g 2Z:305g  
Between the homopolar contacts  
1500VAC/1min (leakage current 1mA)  
Dielectric withstand  
voltage  
Between the heterospolar contacts 1500VAC/1min (leakage current 1mA)  
Contact and coil  
2000VAC/1min (leakage current 1mA)  
25~+55oC  
Ambient temp.  
Insulation resistance  
100MΩ (500VDC)  
073  
Selection Guide  
Contact Parameters  
Product model  
JQX-62F-1Z  
JQX-62F-2Z  
Load  
100A/240VAC 28VDC  
240VAC/28VDC  
≤50mΩ  
100A/240VAC 28VDC  
240VAC/28VDC  
≤50mΩ  
Max. switching voltage  
Contact resistance  
Material  
Contact  
Silver alloy  
Silver alloy  
Coil Specification  
Model & Spec.  
JQX-62F-1Z/2Z  
COIL:220VAC  
JQX-62F-1Z/2Z  
COIL:24VAC  
Rated voltage of coil  
220VAC  
Coil resistance  
Pull-in voltage  
176V AC  
Release voltage  
22V AC  
Rated coil power  
10800  
288  
4.8VA  
2W  
24VAC  
18DC  
2.4AC  
Outline and Installation Dimensions  
Wiring Diagram  
JQX-62F-1Z wiring diagram  
JQX-62F-2Z wiring diagram  
074